VX 3 ø Heat Pump Series

MVX-252WV2GN1; Solution for large residential, villas and commercial buildings

Visit Sales Enquiry Page



Key Features

TypeDetails
HP8
Model nameMVX-252WV2GN1
Power supply | V/Ph/Hz380-415/3/50(60)
Cooling | Capacity | Kw25.2
Cooling | Capacity | kBtu/h86
Cooling | Power input | kw5.3
Cooling | EER4.75
Heating | Capacity |Kw27
Heating |Capacity | kBtu/h92.1
Heating |Power Input | Kw4.82
Heating | COP5.6
Connected indoor unit | Total Capacity50-130% of outdoor unit Capacity
Connected indoor unit | Maximum quantity13
Compressors | TypeDC inverter
Compressors | Quantity1
Fan motors | TypeDC
Fan motors | Quantity1
Fan motors | Static Pressure | Pa0-20 (default); 20-60 (customized)
Refrigerant | TypeR410A
Refrigerant |Factory charge | Kg11
Pipe Connections | Liquid pipe | mmF12.7
Pipe Connections | Gas pipe | mmF25.4
Air Flow rate | m3/h11000
Sound pressure level | dB(A)58
Net dimensions (W×H×D) | mm990×1635×790
Packed dimensions (W×H×D) | mm1090×1805×860
Net weight | Kg227
Gross weight | Kg242
Ambient temp. operation range | Cooling | °C-5 ~ 54
Ambient temp. operation range | Heating | °C-23 ~ 24

Advanced Silent Technology


Reduce ODU noise up to 60% in various scheduling options

Precise Oil Control Technology


Multistage oil control technology recover and take back oil to compressor precisely from entire system

Voting Priority mode


Heating

Vip Mode


Any of unit make VIP, other all will follow the mode of VIP unit only

Special Electrical Protection


Special electrical protection is designed to protect the system from the wrong power supply and prevents the damage of electric control devices

Anti Corrosion Protection


Anti Corrosion Coating is available on-demand for extreme condition

Plate Heat Exchanger


Plate Heat Exchanger (PHE) subcool refrigerant and improves the system's  energy efficiency

Refrigerant Cooling PCB


High heat-generating Electronic components are cooled by refrigerant gas to ensure reliable running at extreme condition

Real Time Refrigerant Amount Monitoring


ODU monitors refrigerant quantity for efficient performance

High Efficiency G type Heat Exchanger


The outdoor unit is equipped with a newly designed high-efficiency G-type heat exchanger, which greatly enlarges the heat exchange area and the efficiency

Self Diagnosis & Auto Protection


Protect units from abnormalities automatically and indicate its fault for fast servicing

Duty Cycling


Equalizes the running time of the unit/compressor to extend lifespan of entire setup

Double Backup Operation


Back up compressor/ unit, facilitate to run the unit uninterrupted thus allowing time for maintenance / repair while maintaining comfort

Rotatable PCB


Rotatable feature make easy accessibility of bottom layer PCB for easy maintenance