Flair 3 Star

Flair 3 Star

Midea's Flair 3 Star has been designed With unique features like Ag+ Nano filter which exhibits Antiviral properties against both bacteria and viruses with a close attachment to the microbial cell/virus particles. Available in three variants 3 kW (1.0), 5 kW (1.5) and 6 kW (2.0).

Category Classification

3kW(1.0) - Rs.31,700
5kW(1.5) - Rs.36,300
6kW(2.0) - Rs.49,100

Download Catalogue Download Manual

AUTO LOUVER MEMORY

When the unit is switched on, the angle of horizontal louvers automatically move to the same position at which they were set previously.

AUTO LOUVER MEMORY

SLEEP MODE

This function automatically increases the temperature by 1˚C per hour for the first two hours, then holds steady for the next 5 hours, and then finally switches off the AC. As a result, this energy-saving mode gives you a comfortable 7-hour sleep.

SLEEP MODE

DEHUMIDIFIER

A humid climate is extremely uncomfortable and causes excessive body perspiration that cannot evaporate in the moisture-saturated air. Dehumidifier allows the air conditioner to reduce the humidity of a specific room while also retaining supreme cooling, keeping the room at a comfortable temperature.

DEHUMIDIFIER

LEAKAGE DETECTOR

The indoor unit shows an error code and stops automatically when the outdoor unit detects refrigerant leakage, thereby making maintenance easier and avoiding the chances of compressor failure.

LEAKAGE DETECTOR

Technical Specifications**

GENERAL

PARAMETER UNIT      
MODEL NO. MACS12FL3T4 MACS18FL3T4 MACS24FL3T4
BEE STAR RATING*** 3 3 3
RATED CAPACITY* '('000W) 3.4 4.9 6.0
NOMINAL POWER INPUT* Watts 1030 1540 1830
RATED POWER SUPPLY Volts/Ph/Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
NET WEIGHT Kgs(IDU/ODU) 9 / 30.5 10.5 / 34 14.2 / 48
AIR FLOW RATE CFM 380 490 680
INDOOR NOISE LEVEL (H/M/L) dB(A) 38/36/32 40/38/35 44/42/40
FAN MOTOR (INDOOR) No.of Speeds 4 4 4
FAN MOTOR (OUTDOOR) No.of Speeds 1 1 1

OVERALL SIZE

INDOOR UNIT (HEIGHT) mm 275 275 315
INDOOR UNIT (WIDTH) mm 800 940 1045
INDOOR UNIT (DEPTH) mm 188 205 235
OUTDOOR UNIT (HEIGHT) mm 540 540 700
OUTDOOR UNIT (WIDTH) mm 780 780 845
OUTDOOR UNIT (DEPTH) mm 250 250 320

FILTERS

ANTI VOC FILTER   YES YES YES
AG + NANO FILTER   YES YES YES
TRI STERILIZATION FILTER   NA NA NA

FEATURES

AUTO RESTART   YES YES YES
CONTROL TYPE   LCD Remote LCD Remote LCD Remote
SUPER TURBO MODE   YES YES YES
AIR DIRECTION CONTROL   YES YES YES
AUTO LOUVER MEMORY   YES YES YES
AUTO ON TIMER   YES YES YES
I- CLEANSER   YES YES YES
FOLLOW ME   YES YES YES
4 WAY SWING   NA NA NA
LEAKAGE DETECTOR   YES YES YES
SLEEP MODE   YES YES YES
DRY MODE   YES YES YES
AUTO FAN SPEED   YES YES YES
AUTO SWING   YES YES YES
REMOTE SCREEN DISPLAY LIGHT   YES YES YES
REFRIGERANT   R22 R22 R22

*All specifications as per IS1391 (Part 2) : 1992 Room air-conditioner. Rounded off as per IS 2:1960 rules for rounding off numerical values.
** Data shown herein is under test pconditions and may vary from model to model. As a continuing policy of product improvement, the design & specifications are subject to change without prior notice.
***BEE (Bureau of Energy Efficiency) an autonomous body under Ministry of Power, Government of India, started this initiative of star rating basis EER ranging from 1 Star to 5 Star.
Max Air Flow Rate mentioned

SUPER TURBO MODESUPER TURBO MODE

In any machine, the normal 'Turbo Mode’ operates for a maximum of 20-30 minutes whereas the ‘Super Turbo Mode’ runs continuously. Once the mode is selected, the AC cools the room quickly and effectively by operating continuously at the maximum fan speed. For effective cooling during high ambient temperatures, Super Turbo mode is recommended.

AG NANO FILTERAG+ NANO FILTER

Ag+ Nano filter exhibits Antiviral properties against both bacteria and viruses with a close attachment to the microbial cell/virus particles.
This close attachment of silver nano particles cause cell lysis mechanism of micro organism after attacking the bacterial cell wall and kills bacteria by strangling them. Highly bioactive silver ions bond with proteins inside and outside bacterial cell membranes thus inhibiting cell respiration and reproduction. Silver also forms stable S-Ag bonds with thiol-containing compounds in the cell membrane that are involved in trans membrane energy generation and ion transport.

LEAKAGE DETECTORLEAKAGE DETECTOR

The indoor unit shows an error code and stops automatically when the outdoor unit detects refrigerant leakage, thereby making maintenance easier and avoiding the chances of compressor failure.

i-CLEANSERi-CLEANSER

When this function is activated, the indoor unit first operates in cooling mode with a low fan speed. During this period, the condensed water takes the dust from the evaporator fins away. It then turns to fan-only mode and blows away the wet air. This whole process disinfects the indoor unit and ensures that all traces of bacteria are removed.

ANTI-VOC FILTERANTI-VOC FILTER

Long-term exposure to Volatile Organic Compounds (VOCs) can damage the liver, kidney and central nervous system. Zero or Anti VOC filter seeks out and eliminates formaldehyde compounds and harmful gases to make sure the air is always healthy and clean.

FOLLOW MEFOLLOW ME

Temperature sensor built within the remote control senses the surrounding temperature. When you stay close to the remote control, the unit will automatically change the operation mode and adjust the room temperature accurately to give you heightened comfort.

i-CHECKi-CHECK

In case of unit malfunction, the AC will not only shut off immediately, but also indicate the error code, resulting in fast service.

SLEEP MODESLEEP MODE

This function automatically increases the temperature by 1˚C per hour for the first two hours, then holds steady for the next 5 hours, and then finally switches off the AC. As a result, this energy-saving mode gives you a comfortable 7-hour sleep.

AUTO RESTARTAUTO RESTART

If the air conditioner breaks off unexpectedly due to a power cut, it will restart with the previous function setting automatically when the power resumes.

AUTO LOUVER MEMORYAUTO LOUVER MEMORY

When the unit is switched on, the angle of horizontal louvers automatically move to the same position at which they were set previously.

RUST FREE CABINETRUST FREE CABINET

Provides protection in extreme weather conditions with its 5 unique layers of protective coating, thereby resulting in complete freedom from rust and longer life.

DEHUMIDIFIERDEHUMIDIFIER

A humid climate is extremely uncomfortable and causes excessive body perspiration that cannot evaporate in the moisture-saturated air. Dehumidifier allows the air conditioner to reduce the humidity of a specific room while also retaining supreme cooling, keeping the room at a comfortable temperature.

AUTO SWINGAUTO SWING

This function controls the angle of the air deflector. It distributes cool/warm air to a maximum area by moving flaps automatically.

24X7 TIMER24X7 TIMER

The timer can be set to start and stop at any point in a 24-hour period.

LEDLED

Control panel of indoor unit adopts LED display.

Other Products

Elektra 365

Elektra 365

3 kW (1.0) MRP Rs. 43,500
5 kW (1.5) MRP Rs. 53,000
6 kW (2.0) MRP Rs. 64,500

View Details
flair

Flair (2 Star)

3 kW (1.0) MRP Rs. 30,200
5 kW (1.5) MRP Rs. 34,800
6 kW (2.0) MRP Rs. 45,900

View Details
elektra 365

Electra 365 Inverter (H&C)

3 kW (1.0) MRP Rs. 44,000
5 kW (1.5) MRP Rs. 53,500
6 kW (2.0) MRP Rs. 65,000

View Details